APDU status word · ISO/IEC 7816-4 · EMV

6A80Incorrect data field

What does APDU response 6A80 mean?

Wrong parameters: incorrect parameters in the command data field.

SW1
6A
SW2
80
Category
Error
Defined in
ISO/IEC 7816-4

In an EMV transaction

  • Often a malformed GPO or GENERATE AC data field — for example a missing 83 template around the PDOL data, or wrongly encoded amounts or dates.

The SW1 6A group

  • SW1 6A means a checking error: wrong parameters P1-P2, with the detail in SW2. SW2 says which check failed, for example 82 for file or application not found.
  • The card appends SW1 SW2 to every response, after any data. Read SW1 first to tell success, warning and error apart, then SW2 for the detail; ISO/IEC 7816-4 groups 61 and 90 as normal processing, 62–63 as warnings, 64–66 as execution errors and 67–6F as checking errors.
  • Other 6A status words with their own page: 6A81 (Function not supported (card blocked)), 6A82 (File or application not found), 6A83 (Record not found), 6A86 (Incorrect P1 P2), 6A88 (Referenced data not found).

Decode any value

Paste any SW1 SW2 status word — including proprietary and card-OS specific values — to look it up in the full list.

Open the APDU Response Codes

Related codes

Something wrong or missing? Report a problem — we check reports against the specs.