Card (ICC)Format: bLength: var
61

Application Template

Tag ID
61
Format
b
Length (bytes)
var
Source
Card (ICC)

What it is

Template holding one directory entry (AID, label, priority) in the PPSE/PSE.

How tag 61 is encoded

EMV data objects are BER-TLV: tag, then length, then value. 61 is a 1-byte, application class, constructed tag (tag number 1), so its value is itself a series of TLV objects that a parser has to walk in turn.

6101100001Bits 8–7 = 01: application class. Bit 6 = 1: constructed. Bits 5–1 give tag number 1.

Length

The length varies, so read it from the length field: one byte for values up to 127 bytes, 81 plus one byte up to 255, 82 plus two bytes beyond that.

Value format b

Format b is binary: the bits mean what this tag defines, with no padding or character conversion.

Who supplies it

The card supplies this value. The terminal reads it from the card’s responses during application selection, GET PROCESSING OPTIONS, READ RECORD or GENERATE AC, depending on where the issuer personalised it.

Specification reference